Do you need a permit to finish a basement in Fort Collins?
Yes. A full or partial basement finish requires a City building permit. The fee is a flat $155 plus sales tax on the total project value, and the work must be done by a City-licensed contractor (license types A, B, B(DR), C1, C2, D1, D2, D(DR) or E residential). Stamped structural plans are needed if you cut new foundation windows, add beams or change structural elements.
Source: Basement Finish Guide, page 2; Building Permits.
What the permit costs
| Item | Amount |
|---|---|
| Building permit, full or partial basement finish | $155 flat |
| Sales tax | On the total project value, materials plus labor |
Some interior work needs no permit at all: painting, wallpapering, tiling, carpeting, cabinets, countertops and similar finish work, and replacing an electrical fixture in the same location. Source: City of Fort Collins, Building Permits.
Which code applies
Permits submitted on or after April 1, 2026 are reviewed under the 2024 International Residential Code (IRC) with Fort Collins local amendments. Source: City of Fort Collins, Building Code.
Inspections you will need

- Rough inspectionsGas line air test, plumbing top-out and water test, rough mechanical, rough electrical, fireplace and rough frame.
- InsulationBefore any drywall goes up.
- FinalWhen the work is complete.
Source: Basement Finish Guide, page 2.
Code requirements, room by room
Ceiling height and bedrooms
- Minimum ceiling height 6 ft 8 in for bedrooms, living areas and hallways; 6 ft 4 in for showers, storage, laundry and similar spaces.
- A bedroom must be at least 70 sq ft and no less than 7 ft in either direction.
- Every bedroom needs an emergency escape and rescue opening. A new below-grade escape window needs a net clear opening of 5.7 sq ft. Replacement windows keep the same or a larger opening, never less than 22 in high, 20 in wide and 4 sq ft.
- New window wells must drain (to the foundation drain if there is one) and have a clear path to the street or sidewalk. Fall protection is required where a new well is next to a door or walking surface.
Smoke and carbon monoxide alarms
- Smoke alarms inside and outside every sleeping area and on each level, interconnected with the existing system if there is one; battery wireless alarms are allowed if not.
- A CO alarm outside and within 15 ft of sleeping areas, and inside bedrooms with a fuel-burning fireplace.
Insulation and windows
- Uninsulated foundation walls: R-19 continuous, or R-13 between studs plus R-5 continuous (the guide lists the accepted options). Exposed rim joists: R-30.
- New or replacement windows: U-factor 0.28 maximum, SHGC 0.35 maximum.
- Bottom plates touching concrete must be pressure-treated lumber.
Electrical
- AFCI, GFCI and tamper-resistant protection on all basement receptacles, including wet bars (bathroom receptacles do not need AFCI).
- Bathrooms need a dedicated 20-amp GFCI circuit; in habitable rooms, outlets no more than 12 ft apart along the wall.
Bathrooms, plumbing and ventilation
- A bathroom needs an exhaust fan ducted outside or an operable window.
- New basement fixtures need an approved backwater valve.
- Low-flow fixtures: toilets 1.28 gallons per flush, showers 1.8 gpm, faucets 1.5 gpm.
- Habitable rooms need natural ventilation (openable area of at least 4% of the floor area) and, with forced-air systems, supply and return air to every habitable room.
Fire safety details
- Usable space under stairs must be protected with at least ½ in drywall.
- Fire blocking at ceilings and every 10 ft in furred walls.
- Mechanical rooms may not open into a bedroom or bathroom, with limited exceptions.
Source for this section: City of Fort Collins Basement Finish Guide, pages 4 and 5. If your home has a fire sprinkler system, contact the City before you apply (page 2). Planning to live down there? Read radon and clay soils first.